PG Drives VR2 fault code Gauge blinks every 2.5 seconds: Sleep mode
CodeGauge blinks every 2.5 seconds CONFIRMED
MeaningSleep mode
ControllerVR2 powerchair controller CONFIRMED
How it showsBattery gauge on the VR2 joystick flashes 1 to 10 bars (red, amber, green). Speed LEDs flashing with the gauge (+S) = communication fault; actuator LED flashing with the gauge (+A) = actuator trip
Likely causes
The controller has gone to sleep after a period without use
Step-by-step checks
- Switch off and on again
Switch off before unplugging anything. If the code stays after these checks, get a trained technician to look at it.
Models using this controller
- Sunrise Medical (Quickie) Quickie Q100 R
- Sunrise Medical (Quickie) Quickie Q200 R
- Eden Mobility (own brand) Jupiter (2nd & 3rd gen)
- Eden Mobility (own brand) Comet
- Eden Mobility (own brand) Apollo
- Eden Mobility (own brand) Venus
- Pride Mobility Jazzy Select (UK)
- Drive DeVilbiss Enigma Energi+
- Drive DeVilbiss Enigma Energi (from 2006)
- Drive DeVilbiss Mambo (fixed base)
Other PG Drives VR2 codes
1 bar · 2 bars · 4 bars · 3 bars · 5 bars · 6 bars · 7 bars · 8 bars · 9 bars · 10 bars · Speed LEDs flash with the gauge (+S) · Actuator LED flashes with the gauge (+A) · Battery gauge steps up · Speed indicator ripples up and down · Speed indicator flashes · Battery gauge ripples at power-on · Gauge blinks every 2.5 seconds
Source: www.bettermobility.co.uk/downloads/Drive-Medical-powerchair-flash-code ↗
Summarised from public manuals. Always check the product's own manual before any repair.