Eden Mobility (own brand) Comet – fault codes, parts & serial label
Typepowerchair
ControllerPG Drives VR2 (per dealer workshop poster) CONFIRMED
Fault codes (17)
From the VR2 powerchair controller code set. All VR2 powerchair controller codes
| Code | Meaning | Checks |
|---|---|---|
| 1 bar | Low battery voltage | Check the connections to the battery. If the connections are good, try charging the battery |
| 2 bars | Left motor disconnected | Check all the connections and leads between the left motor and the power module |
| 4 bars | Right motor disconnected | Check all the connections and leads between the right motor and the power module |
| 3 bars | Left motor wiring trip | Check all the connections and leads between the left motor and the battery |
| 5 bars | Right motor wiring trip | Check all the connections and leads between the right motor and the battery |
| 6 bars | Charger connected (drive inhibited) | Disconnect the battery charger; otherwise find the external inhibit signal for this chair |
| 7 bars | Possible joystick trip | Make sure the joystick is in the centre position before switching on the VR2 |
| 8 bars | Possible control system trip | Make sure that all connections are secure |
| 9 bars | Solenoid brake trip | Check the parking brake and motor connections. Make sure all the system connections are secure |
| 10 bars | High battery voltage | Check the battery connections |
| Speed LEDs flash with the gauge (+S) | Communication fault | Check the cable and plugs between joystick and power module; cycle the power |
| Actuator LED flashes with the gauge (+A) | Actuator trip | Check the actuator wiring and plugs |
| Battery gauge steps up | Charging (drive inhibited) | No drive until the charger is unplugged and the power switched off and on |
| Speed indicator ripples up and down | Chair locked | Unlock it with the key or the joystick unlock sequence in the chair manual |
| Speed indicator flashes | Speed limited | Lower the seat to drive at full speed |
| Battery gauge ripples at power-on | Joystick displaced | Centre the joystick, switch off and on again |
| Gauge blinks every 2.5 seconds | Sleep mode | Switch off and on again |
Serial code label
No serial location data yet for this powerchair. Serial codes
Parts (0)
No parts recorded for this model yet.
Summarised from public manuals and supplier listings. Always check the product's own manual before any repair.