Dynamic SHARK fault codes

MakerDynamic Controls (Allient NZ) CONFIRMED
How codes showFault indicator on the SHARK Remote flashes a number of times, pause, repeat

Codes (8)

CodeMeaning
1 flashRoute / temperature: motor current at maximum for too long, or SHARK Power Module too hot CONFIRMED
2 flashesBattery voltage too low or too high CONFIRMED
3 flashesMotor 1 (usually left) not connected to the SHARK, or short circuit in the motor connection CONFIRMED
4 flashesMotor 2 (usually right) not connected to the SHARK, or short circuit in the motor connection CONFIRMED
5 flashesParkbrake 1 (usually left) released manually, not connected to the SHARK, or short circuit in the parkbrake connection CONFIRMED
6 flashesParkbrake 2 (usually right) released manually, not connected to the SHARK, or short circuit in the parkbrake connection CONFIRMED
9 flashesCommunication error between the Remote and the Power Module (poster label reads 'Parkbrake 2 (usually right)', likely a misprint) INFERRED
All other flashesInternal fault CONFIRMED

Codes without a link are status lights or not used, so they don't have their own page.

Models using this controller

Notes: Powerchair controller (moved to the Powerchairs section 2026-10-26). Verified from the dealer workshop poster. Poster footnote: these descriptions are aimed at end users; see the SHARK Power Module installation manual for detail. Poster flash 9 is labelled 'Parkbrake 2 (usually right)' but its meaning is a Remote to Power Module communication error, so the label looks like a misprint. Flashes 7 and 8 are not listed on the poster (covered by 'All other'). Not the same as DYN-RHINO2-SHARK (a Rhino2 scooter controller set to the Shark flash type), whose code meanings differ.

Summarised from public manuals. Always check the product's own manual before any repair.