‹ All models

Drive DeVilbiss Powerchair on SHARK (model not named) – fault codes, parts & serial label

Typepowerchair
ControllerDynamic SHARK (per dealer workshop poster, 'Drive') INFERRED

Fault codes (8)

From the SHARK powerchair control system (Remote + Power Module) code set. All SHARK powerchair control system (Remote + Power Module) codes

CodeMeaningChecks
1 flashRoute / temperature: motor current at maximum for too long, or SHARK Power Module too hotTurn off the SHARK, let it cool, turn it back on and choose another route; make sure the wheels turn freely; have the motor(s) checked by a service technician; if too hot wait a few minutes and try again, and if it happens often contact Dynamic
2 flashesBattery voltage too low or too highCheck the batteries and cables; charge the batteries; if overcharged downhill, slow down or turn on the lights (if fitted); damaged batteries or charger fault: contact your dealer; check the battery cables and connectors
3 flashesMotor 1 (usually left) not connected to the SHARK, or short circuit in the motor connectionTurn the wheels of the chair to reconnect the motor brushes, then turn the SHARK off and on (if this happens often the motors may be faulty); check the motor cables are not loose or damaged; contact your dealer
4 flashesMotor 2 (usually right) not connected to the SHARK, or short circuit in the motor connectionTurn the wheels of the chair to reconnect the motor brushes, then turn the SHARK off and on (if this happens often the motors may be faulty); check the motor cables are not loose or damaged; contact your dealer
5 flashesParkbrake 1 (usually left) released manually, not connected to the SHARK, or short circuit in the parkbrake connectionEnable the parkbrake, then turn the SHARK off and on; check the motor cables are not loose or damaged; contact your dealer
6 flashesParkbrake 2 (usually right) released manually, not connected to the SHARK, or short circuit in the parkbrake connectionEnable the parkbrake, then turn the SHARK off and on; check the motor cables are not loose or damaged; contact your dealer
9 flashesCommunication error between the Remote and the Power Module (poster label reads 'Parkbrake 2 (usually right)', likely a misprint)Charge the batteries; damaged batteries: contact your dealer; check the SHARK Bus cable is not loose or damaged; contact your dealer
All other flashesInternal faultContact your dealer

Serial code label

No serial location data yet for this powerchair. Serial codes

Parts (0)

No parts recorded for this model yet.

Summarised from public manuals and supplier listings. Always check the product's own manual before any repair.