MakerDynamic Controls (Rhino / Rhino2) CONFIRMED
How codes showFlashes on tiller LED 1–10
Codes (10)
| Code | Meaning |
|---|---|
| 1 flash | Charge batteries (still drives) |
| 2 flashes | Battery voltage too low |
| 3 flashes | Battery voltage too high |
| 4 flashes | Power time exceeded |
| 5 flashes | Brake failure |
| 6 flashes | No neutral at switch-on / circuit board |
| 7 flashes | Speed pot fault |
| 8 flashes | Motor voltage error |
| 9 flashes | Miscellaneous internal fault |
| 10 flashes | Push / freewheel overspeed |
Codes without a link are status lights or not used, so they don't have their own page.
Models using this controller
Notes: Invacare service manuals name the power modules.
Summarised from public manuals. Always check the product's own manual before any repair.