Shoprider AC / AC2 fault code Alarm 2s span (0.2 on/1.8 off): Speed command error

CodeAlarm 2s span (0.2 on/1.8 off)
MeaningSpeed command error
ControllerShoprider AC (analogue) / AC2 (digital) controller CONFIRMED
How it showsBeeper/LED alarm patterns (span/on/off timing)
Likely part needed: Throttle pot INFERRED – only if the checks below point to it. Find it ›

Likely causes

Wig-wag (5kΩ) or speed VR (20kΩ) pot damaged/shorted; neutral needs resetting

Step-by-step checks

  1. Check pots
  2. Reset neutral

Switch off before unplugging anything. If the code stays after these checks, get a trained technician to look at it.

Parts that usually fix this INFERRED

Matched by ScootScan from the fault description to parts listed for models that use this controller. Do the checks first – many faults are fixed by charging, a loose plug or a reset – and check the part fits your model before ordering.

Potentiometer assembly · part no. 106108-66404-A2
Throttle pot listed for the Shoprider (Pihsiang) Cordoba
Potentiometer · part no. 206103-88103-A2
Throttle pot listed for the Shoprider (Pihsiang) Cordoba

Some links may be affiliate links; we may earn a small commission at no extra cost to you. As an Amazon Associate I earn from qualifying purchases.

Models using this controller

Other Shoprider AC / AC2 codes

Alarm 0.3s span (0.2 on/0.1 off) · Alarm 5s span (4 on/1 off) · Alarm 0.4s span (0.3 on/0.1 off) · Alarm 2s span (0.2 on/1.8 off)

All Shoprider AC / AC2 codes ›

Source: www.gewizrepairs.co.uk/shoprider_service_manual.pdf ↗

Summarised from public manuals. Always check the product's own manual before any repair.