Handicare 1100 – fault codes, parts & serial label
Typestraight
Years / revisioncurrent
Control board1100 display CONFIRMED
Fault codes (14)
From the 1100 straight display code set. All 1100 straight display codes
| Code | Meaning | Checks |
|---|---|---|
| 0 | Lift switched off by key/stop | Turn the key on; release the stop |
| - | Armrest up or seat swivelled | Lower arms; lock seat |
| 2 | Not recharging (beeps ~40 s) | Move to the charge point |
| 4 / 6 | Obstacle – runs one way only | Drive away and remove obstacle |
| 7 | Battery too low | Wait about 30 min on charge |
| 8 / 9 | Driving | Nothing to do |
| 1 | Needs charge | Charge |
| 3 | Top limit | Normal at end |
| 5 | Bottom limit | Normal at end |
| d | Main relay not open | Engineer |
| L | Motor fault (engineer guide) – meaning disputed | Engineer |
| o | Memory fault | Engineer |
| y | Hardware fault | Engineer |
| FP | Footplate fault | Check footplate is down; engineer |
Serial code label
No serial location data yet for this stairlift. Serial codes
Parts (5)
| Part | Part no. |
|---|---|
| Minivator / Handicare 1100 battery set | |
| Minivator / Handicare 1100 Battery Set – Longway | |
| Handicare 1100 Charger | |
| Handicare 1100 Main PCB | |
| Handicare 1100 Complete Drive Motor & Gearbox Set |
Summarised from public manuals and supplier listings. Always check the product's own manual before any repair.